Form Factor
|
- Single Connected Grid Module, no slot placement restrictions
|
Dimensions (H x W x D)
|
- 1.50” x 4.24” x 5.25”
- 3.81 cm x 10.77 cm x 13.34 cm
|
Weight
|
- 0.5 lbs (0.23 kg)
|
Radio Capabilities
|
World Wide Frequency support
|
- North America- ISM: 902-928 MHz
- Australia: 915-928 MHz
- Brazil: 902-907.5, 915-928 MHz
- Hong Kong: 920-924 MHz
|
Radio Access Method
|
- IEEE802.15.4 g/e
|
Frequency Hopping Spread Spectrum
|
- 64 channels (depending on regulatory domain), 400 KHz per channel
|
Antenna Interfaces
|
- 1 Antenna ports- QMA connector
|
Output transmit power (average power):
|
- 30 dBm
|
Link Budget
|
- Over 136 dB (up to 148 dB depending on antenna gain)
|
Receiver Sensitivity
|
- -106 dBm
|
Operating Conditions
|
Operating Temperature
|
-40º F to 158º F (-40 to +70º C) continuous operating temperature range with IEEE 1613 type for up to +85 C for 16 hours
|
Shock and Vibration
|
- 30G at 6 ms, Class Cm
- IEEE 1613 Class VS3
- IEC 870-2-2 Class Cm
|
Operating Seismic Earthquake
|
IEC 61850-3, Class S3
|
Altitude
|
10,000 ft (3,048 m) maximum operating temperature is de-rated with increasing altitude per IEEE1613a-2008
|
Relative Humidity
|
5 to 95 percent non-condensing
|
Non-operating Conditions
|
Temperature
|
-40º to +185º F (-25º C to +85º C)
|
Non-operating Relative Humidity
|
5 to 95 percent non-condensing
|
Altitude
|
10,000 ft (3000 m); maximum operating temperature is de-rated with increasing altitude per IEEE 1613a-2008
|
Non-operating Free-fall Drop
|
4 in. (100 mm) per ENG-339611
|
Non-operating Shock and Vibration
|
- 50-60 G (3.76 m/s minimum)
- 3-500 Hz at 1.12 GRMS (BP at 10 and 100 Hz)
|
Immunity
|
- EN61000-6-2
- EN61000-4-2 (ESD)
- EN61000-4-3 (RF)
- EN61000-4-4 (EFT)
- EN61000-4-5 (SURGE)
- EN61000-4-6 (CRF)
- EN61000-4-11 (VDI)
- EN 55024, CISPR 24
- EN50082-1
|
Safety
|
- USA: UL 60950-1
- Canada: CAN/CSA C22.2 No. 60950-1
- Europe: EN 60950-1
- China: GB 60950-1
- Australia/New Zealand: AS/NZS 60950-1
- Rest of World: IEC 60950-1
- CSA-certified to UL/CSA 60950-1, 2nd Ed.
- CB report to IEC60950-1, 2nd Ed., covering all group differences and national deviations.
|
Electromagnetic Compliance
|
- 47 CFR, Part 15
- ICES-003 Class A
- EN55022 Class A
- CISPR22 Class A
- AS/NZS 3548 Class A
- VCCI V-3
- CNS 13438
- EN 300-386
|
Radio
|
- FCC Part 2, FCC Part 15.247, Part 90.210
- Brazil: ANATEL Resolution No. 506
- Australia: AS/NZS 4268:2008
- China: 1049 Issue 1
|
Bạn đang cần tư vấn về sản phẩm: CGM-WPAN-FSK-NA ?