Feature |
Description |
Protocols |
● Fibre Channel standards
● FC-PH, Revision 4.3 (ANSI INCITS 230-1994)
● FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996)
● FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999)
● FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997)
● FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998)
● FC-PI, Revision 13 (ANSI INCITS 352-2002)
● FC-PI-2, Revision 10 (ANSI INCITS 404-2006)
● FC-PI-3, Revision 4 (ANSI INCITS 460-2011)
● FC-PI-4, Revision 8 (ANSI INCITS 450-2008)
● FC-PI-5, Revision 6 (ANSI INCITS 479-2011)
● FC-PI-6 (ANSI INCITS 512-2015)
● FC-FS, Revision 1.9 (ANSI INCITS 373-2003)
● FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007)
● FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007)
● FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011)
● FC-FS-4
● FC-LS, Revision 1.62 (ANSI INCITS 433-2007)
● FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011)
● FC-LS-3, Includes revision 3.53
● FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001)
● FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004)
● FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006)
● FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010)
● FC-SW-6
● FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001)
● FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004)
● FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007)
● FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010)
● FC-GS-7, Includes revision 10.8
● FCP, Revision 12 (ANSI INCITS 269-1996)
● FCP-2, Revision 8 (ANSI INCITS 350-2003)
● FCP-3, Revision 4 (ANSI INCITS 416-2006)
● FCP-4, Revision 2b (ANSI INCITS 481-2011)
● FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001)
● FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003)
● FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007)
● FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011)
● FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014)
● FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014)
● FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003)
● FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006)
● FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008)
● FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010)
● FC-VI, Revision 1.84 (ANSI INCITS 357-2002)
● FC-SP, Revision 1.8 (ANSI INCITS 426-2007)
● FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012)
● FAIS, Revision 1.03 (ANSI INCITS 432-2007)
● FAIS-2, Revision 2.23 (ANSI INCITS 449-2008)
● FC-IFR, Revision 1.06 (ANSI INCITS 475-2011)
● FC-FLA, Revision 2.7 (INCITS TR-20-1998)
● FC-PLDA, Revision 2.1 (INCITS TR-19-1998)
● FC-Tape, Revision 1.17 (INCITS TR-24-1999)
● FC-MI, Revision 1.92 (INCITS TR-30-2002)
● FC-MI-2, Revision 2.6 (INCITS TR-39-2005)
● FC-MI-3, Revision 1.03 (INCITS TR-48-2012)
● FC-DA, Revision 3.1 (INCITS TR-36-2004)
● FC-DA-2, Revision 1.06 (INCITS TR-49-2012)
● FC-MSQS, Revision 3.2 (INCITS TR-46-2011)
● Fibre Channel classes of service: Class 2, Class 3, and Class F
● Fibre Channel standard port types: E, F, and B
● Fibre Channel enhanced port types: SD, ST, NP and TE
● NVMe/FC
● In-band management using IP over Fibre Channel (RFC 2625)
● IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338)
● Extensive IETF-standards-based TCP/IP, SNMPv3, and Remote Monitoring (RMON) MIBs |
Fibre Channel ports |
● Fixed switch form factor with 16 SFP+ ports base and one 16 SFP+ port expansion slot
● Entry-level 8-port preactivated base model with flexibility to turn on any 8 ports
● Incremental ports
◦ On the 8-port base model, with the 8-Port On- Demand Activation license to activate up to 16 ports on the base switch
◦ On the 8-port base model, with the 16-port expansion module to activate up to 24 ports
◦ On the 16-port configuration, with the 16-port expansion module to activate up to 32 ports
◦ On the 24-port configuration, with the 8-Port On- Demand Activation license to activate up to 32 ports
|
Security |
● VSAN fabric isolation
● Intelligent packet inspection @ port level
● Hardware zoning by Access Control Lists (ACLs)
● FC-SP switch-to-switch authentication
● FC-SP host-to-switch authentication
● RBAC using RADIUS, TACACS+ or LDAP Authentication, Authorization, and Accounting (AAA) functions
● Secure FTP (SFTP)
● Secure Shell Version 2 (SSHv2)
● Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES)
● Control-plane security
● Cisco TrustSec payload encryption
● Secure Boot and Anti-counterfeit technology |
Performance |
● Port speed: 4/8/16/32-Gbps autosensing with 32 Gbps of dedicated bandwidth per port
● Aggregate bandwidth of 1024 Gbps end-to-end full duplex
● Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group
● Port channel: Up to 16 load-balanced physical links grouped in one port channel |
Diagnostics |
● Power-on-Self-Test (POST) diagnostics
● Online Health Management System (OHMS) diagnostics
● Internal loopbacks
● SPAN
● Fibre Channel traceroute
● Fibre Channel ping
● Fibre Channel debug
● Cisco Fabric Analyzer
● Syslog
● Port-level statistics
● Link Diagnostics (ISL Diagnostics and HBA Diagnostics)
● Read Diagnostic Parameter |
Serviceability |
● Configuration file management
● Call Home
● Port beaconing
● Link Cable Beacon
● System LEDs
● SNMP traps for alerts |
Reliability and availability |
● Cisco In-Service Software Upgrade (ISSU)
● Hot-swappable, dual redundant power supplies
● Hot-swappable fan module with switch integrated temperature and power management
● Hot-swappable SFP+ optics
● Stateful process restart
● Any port configuration for port channels
● Fabric-based multi pathing
● Per-VSAN fabric services
● Port tracking
● VRRP for management IP interface |
Network management |
● Management access through 2 out-of-band 10/100/1000 Mbps Ethernet ports
◦ mgmt0: 10/100/1000BASE-T port
◦ mgmt1: 10/100/1000BASE-T port
● RS-232 serial console port
● USB power-on auto-provision port
● Access protocols
● Command-Line Interface (CLI) using the console and Ethernet port
● SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access
● Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S)
● NX-API for restful access via HTTPS
● Distributed device alias service
● Network security
● Per-VSAN Role-Based Access Control (RBAC) using LDAP, RADIUS and TACACS+-based Authentication, Authorization, and Accounting (AAA) functions
● SFTP
● SSHv2 implementing AES
● SNMPv3 implementing AES
● Cisco Data Center Network Manager
|
Programming interfaces |
● Scriptable CLI
● Cisco DCNM web services API
● NX-API restful interfaces
● On-board Python interpreter
● Cisco Embedded Event Manager
● Cisco NX-OS Software scheduler |
Physical dimensions (HxWxD) and weight |
● 1RU (1.72 inches x 17.3 inches x 20.11 inches) excluding Power Supply Unit (PSU) and fan module handles
● 9.1 kg with 16 activated ports
● 9.82 kg with all 32 activated ports |
Power |
● 80 Plus Platinum certified power supplies
● Power supply options
◦ 650W AC in base model, port-side exhaust variant (up to 2 per switch)
◦ 650W AC in base model, port-side intake variant (up to 2 per switch)
● Power cord
◦ IEC60320 C14 plug on 650W power supply connecting to a notched C15 socket connector (check Table 6 for power cords specific to regions)
● AC input: 100 to 240V AC (10% range)
● Frequency: 50 to 60 Hz (nominal)
● Typical power consumption
◦ 72W for idle base switch with 16 ports activated without SFPs
◦ 43W for idle expansion module with 16 ports activated without SFPs
◦ 80W for 8 ports activated with 32G SFPs with traffic at 25°C
● Airflow
◦ Back to front (toward ports) using port-side exhaust fans
◦ Front to back (inward from ports) using port-side intake fans
◦ 50 Cubic Feet per Minute (CFM) through system fan assembly at 25°C
◦ 100 CFM maximum
|
Temperature range |
● Temperature, ambient operating:
◦ 32 to 104°F (0 to 45°C) with port-side exhaust and Intake airflow variants
● Temperature, ambient nonoperating and storage: -40 to 158°F (-40 to 70°C)
● Relative humidity, ambient (noncondensing) operating: 10 to 90%
● Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95%
● Altitude, operating: -197 to 6500 ft (-60 to 2000m)
|
Approvals and compliance |
● Safety compliance
● CE Marking
● UL 60950
● CAN/CSA-C22.2 No. 60950
● EN 60950
● IEC 60950
● TS 001
● AS/NZS 3260
● IEC60825
● EN60825
● 21 CFR 1040
● EMC compliance
● FCC Part 15 (CFR 47) Class A
● ICES-003 Class A
● EN 55022 Class A
● CISPR 22 Class A
● AS/NZS 3548 Class A
● VCCI Class A
● EN 55024
● EN 50082-1
● EN 61000-6-1
● EN 61000-3-2
● EN 61000-3-3 |
Fabric services |
● Name server
● Registered State Change Notification (RSCN)
● Login services
● Fabric Configuration Server (FCS)
● Broadcast
● In-order delivery |
Advanced functions |
● VSAN
● NPV
● IVR
● Port channel with multipath load balancing
● Flow-based and zone-based QoS |
Supported Cisco optics, media, and transmission distances |
● For detailed information about all supported transceivers, see Cisco MDS 9000 Family pluggable transceivers documentation |
Bạn đang cần tư vấn về sản phẩm: DS-C9132T-MEK9 ?