| Feature | 
			Description | 
		
		
			| Protocols | 
			●  Fibre Channel standards 
			●  FC-PH, Revision 4.3 (ANSI INCITS 230-1994) 
			●  FC-PH, Amendment 1 (ANSI INCITS 230-1994/AM1-1996) 
			●  FC-PH, Amendment 2 (ANSI INCITS 230-1994/AM2-1999) 
			●  FC-PH-2, Revision 7.4 (ANSI INCITS 297-1997) 
			●  FC-PH-3, Revision 9.4 (ANSI INCITS 303-1998) 
			●  FC-PI, Revision 13 (ANSI INCITS 352-2002) 
			●  FC-PI-2, Revision 10 (ANSI INCITS 404-2006) 
			●  FC-PI-3, Revision 4 (ANSI INCITS 460-2011) 
			●  FC-PI-4, Revision 8 (ANSI INCITS 450-2008) 
			●  FC-PI-5, Revision 6 (ANSI INCITS 479-2011) 
			●  FC-PI-6 (ANSI INCITS 512-2015) 
			●  FC-FS, Revision 1.9 (ANSI INCITS 373-2003) 
			●  FC-FS-2, Revision 1.01 (ANSI INCITS 424-2007) 
			●  FC-FS-2, Amendment 1 (ANSI INCITS 424-2007/AM1-2007) 
			●  FC-FS-3, Revision 1.11 (ANSI INCITS 470-2011) 
			●  FC-FS-4 
			●  FC-LS, Revision 1.62 (ANSI INCITS 433-2007) 
			●  FC-LS-2, Revision 2.21 (ANSI INCITS 477-2011) 
			●  FC-LS-3, Includes revision 3.53 
			●  FC-SW-2, Revision 5.3 (ANSI INCITS 355-2001) 
			●  FC-SW-3, Revision 6.6 (ANSI INCITS 384-2004) 
			●  FC-SW-4, Revision 7.5 (ANSI INCITS 418-2006) 
			●  FC-SW-5, Revision 8.5 (ANSI INCITS 461-2010) 
			●  FC-SW-6 
			●  FC-GS-3, Revision 7.01 (ANSI INCITS 348-2001) 
			●  FC-GS-4, Revision 7.91 (ANSI INCITS 387-2004) 
			●  FC-GS-5, Revision 8.51 (ANSI INCITS 427-2007) 
			●  FC-GS-6, Revision 9.4 (ANSI INCITS 463-2010) 
			●  FC-GS-7, Includes revision 10.8 
			●  FCP, Revision 12 (ANSI INCITS 269-1996) 
			●  FCP-2, Revision 8 (ANSI INCITS 350-2003) 
			●  FCP-3, Revision 4 (ANSI INCITS 416-2006) 
			●  FCP-4, Revision 2b (ANSI INCITS 481-2011) 
			●  FC-SB-2, Revision 2.1 (ANSI INCITS 349-2001) 
			●  FC-SB-3, Revision 1.6 (ANSI INCITS 374-2003) 
			●  FC-SB-3, Amendment 1 (ANSI INCITS 374-2003/AM1-2007) 
			●  FC-SB-4, Revision 3.0 (ANSI INCITS 466-2011) 
			●  FC-SB-5, Revision 2.00 (ANSI INCITS 485-2014) 
			●  FC-BB-6, Revision 2.00 (ANSI INCITS 509-2014) 
			●  FC-BB-2, Revision 6.0 (ANSI INCITS 372-2003) 
			●  FC-BB-3, Revision 6.8 (ANSI INCITS 414-2006) 
			●  FC-BB-4, Revision 2.7 (ANSI INCITS 419-2008) 
			●  FC-BB-5, Revision 2.0 (ANSI INCITS 462-2010) 
			●  FC-VI, Revision 1.84 (ANSI INCITS 357-2002) 
			●  FC-SP, Revision 1.8 (ANSI INCITS 426-2007) 
			●  FC-SP-2, Revision 2.71 (ANSI INCITS 496-2012) 
			●  FAIS, Revision 1.03 (ANSI INCITS 432-2007) 
			●  FAIS-2, Revision 2.23 (ANSI INCITS 449-2008) 
			●  FC-IFR, Revision 1.06 (ANSI INCITS 475-2011) 
			●  FC-FLA, Revision 2.7 (INCITS TR-20-1998) 
			●  FC-PLDA, Revision 2.1 (INCITS TR-19-1998) 
			●  FC-Tape, Revision 1.17 (INCITS TR-24-1999) 
			●  FC-MI, Revision 1.92 (INCITS TR-30-2002) 
			●  FC-MI-2, Revision 2.6 (INCITS TR-39-2005) 
			●  FC-MI-3, Revision 1.03 (INCITS TR-48-2012) 
			●  FC-DA, Revision 3.1 (INCITS TR-36-2004) 
			●  FC-DA-2, Revision 1.06 (INCITS TR-49-2012) 
			●  FC-MSQS, Revision 3.2 (INCITS TR-46-2011) 
			●  Fibre Channel classes of service: Class 2, Class 3, and Class F 
			●  Fibre Channel standard port types: E, F, and B 
			●  Fibre Channel enhanced port types: SD, ST, NP and TE 
			●  NVMe/FC 
			●  In-band management using IP over Fibre Channel (RFC 2625) 
			●  IPv6, IPv4, and Address Resolution Protocol (ARP) over Fibre Channel (RFC 4338) 
			●  Extensive IETF-standards-based TCP/IP, SNMPv3, and Remote Monitoring (RMON) MIBs | 
		
		
			| Fibre Channel ports | 
			
			 ●  Fixed switch form factor with 16 SFP+ ports base and one 16 SFP+ port expansion slot 
			●  Entry-level 8-port preactivated base model with flexibility to turn on any 8 ports 
			●  Incremental ports 
			◦      On the 8-port base model, with the 8-Port On- Demand Activation license to activate up to 16 ports on the base switch 
			◦      On the 8-port base model, with the 16-port expansion module to activate up to 24 ports 
			◦      On the 16-port configuration, with the 16-port expansion module to activate up to 32 ports 
			◦      On the 24-port configuration, with the 8-Port On- Demand Activation license to activate up to 32 ports 
			 | 
		
		
			| Security | 
			●  VSAN fabric isolation 
			●  Intelligent packet inspection @ port level 
			●  Hardware zoning by Access Control Lists (ACLs) 
			●  FC-SP switch-to-switch authentication 
			●  FC-SP host-to-switch authentication 
			●  RBAC using RADIUS, TACACS+ or LDAP Authentication, Authorization, and Accounting (AAA) functions 
			●  Secure FTP (SFTP) 
			●  Secure Shell Version 2 (SSHv2) 
			●  Simple Network Management Protocol Version 3 (SNMPv3) implementing Advanced Encryption Standard (AES) 
			●  Control-plane security 
			●  Cisco TrustSec payload encryption 
			●  Secure Boot and Anti-counterfeit technology | 
		
		
			| Performance | 
			●  Port speed: 4/8/16/32-Gbps autosensing with 32 Gbps of dedicated bandwidth per port 
			●  Aggregate bandwidth of 1024 Gbps end-to-end full duplex 
			●  Buffer credits: Up to 8300 for a group of 16 ports, with a default of 500 buffer credits per port and a maximum of 8270 buffer credits for a single port in the group 
			●  Port channel: Up to 16 load-balanced physical links grouped in one port channel | 
		
		
			| Diagnostics | 
			●  Power-on-Self-Test (POST) diagnostics 
			●  Online Health Management System (OHMS) diagnostics 
			●  Internal loopbacks 
			●  SPAN 
			●  Fibre Channel traceroute 
			●  Fibre Channel ping 
			●  Fibre Channel debug 
			●  Cisco Fabric Analyzer 
			●  Syslog 
			●  Port-level statistics 
			●  Link Diagnostics (ISL Diagnostics and HBA Diagnostics) 
			●  Read Diagnostic Parameter | 
		
		
			| Serviceability | 
			●  Configuration file management 
			●  Call Home 
			●  Port beaconing 
			●  Link Cable Beacon 
			●  System LEDs 
			●  SNMP traps for alerts | 
		
		
			| Reliability and availability | 
			●  Cisco In-Service Software Upgrade (ISSU) 
			●  Hot-swappable, dual redundant power supplies 
			●  Hot-swappable fan module with switch integrated temperature and power management 
			●  Hot-swappable SFP+ optics 
			●  Stateful process restart 
			●  Any port configuration for port channels 
			●  Fabric-based multi pathing 
			●  Per-VSAN fabric services 
			●  Port tracking 
			●  VRRP for management IP interface | 
		
		
			| Network management | 
			
			 ●  Management access through 2 out-of-band 10/100/1000 Mbps Ethernet ports 
			◦      mgmt0: 10/100/1000BASE-T port 
			◦      mgmt1: 10/100/1000BASE-T port 
			●  RS-232 serial console port 
			●  USB power-on auto-provision port 
			●  Access protocols 
			●  Command-Line Interface (CLI) using the console and Ethernet port 
			●  SNMPv3 using the Ethernet port and in-band IP over Fibre Channel access 
			●  Storage Networking Industry Association (SNIA) Storage Management Initiative Specification (SMI-S) 
			●  NX-API for restful access via HTTPS 
			●  Distributed device alias service 
			●  Network security 
			●  Per-VSAN Role-Based Access Control (RBAC) using LDAP, RADIUS and TACACS+-based Authentication, Authorization, and Accounting (AAA) functions 
			●  SFTP 
			●  SSHv2 implementing AES 
			●  SNMPv3 implementing AES 
			●  Cisco Data Center Network Manager 
			 | 
		
		
			| Programming interfaces | 
			●  Scriptable CLI 
			●  Cisco DCNM web services API 
			●  NX-API restful interfaces 
			●  On-board Python interpreter 
			●  Cisco Embedded Event Manager 
			●  Cisco NX-OS Software scheduler | 
		
		
			| Physical dimensions (HxWxD) and weight | 
			●  1RU (1.72 inches x 17.3 inches x 20.11 inches) excluding Power Supply Unit (PSU) and fan module handles 
			●  9.1 kg with 16 activated ports 
			●  9.82 kg with all 32 activated ports | 
		
		
			| Power | 
			
			 ●  80 Plus Platinum certified power supplies 
			●  Power supply options 
			◦      650W AC in base model, port-side exhaust variant (up to 2 per switch) 
			◦      650W AC in base model, port-side intake variant (up to 2 per switch) 
			●  Power cord 
			◦      IEC60320 C14 plug on 650W power supply connecting to a notched C15 socket connector (check Table 6 for power cords specific to regions) 
			●  AC input: 100 to 240V AC (10% range) 
			●  Frequency: 50 to 60 Hz (nominal) 
			●  Typical power consumption 
			◦      72W for idle base switch with 16 ports activated without SFPs 
			◦      43W for idle expansion module with 16 ports activated without SFPs 
			◦      80W for 8 ports activated with 32G SFPs with traffic at 25°C 
			●  Airflow 
			◦      Back to front (toward ports) using port-side exhaust fans 
			◦   Front to back (inward from ports) using port-side intake fans 
			◦   50 Cubic Feet per Minute (CFM) through system fan assembly at 25°C 
			◦   100 CFM maximum 
			 | 
		
		
			| Temperature range | 
			
			 ●  Temperature, ambient operating: 
			◦      32 to 104°F (0 to 45°C) with port-side exhaust and Intake airflow variants 
			●  Temperature, ambient nonoperating and storage: -40 to 158°F (-40 to 70°C) 
			●  Relative humidity, ambient (noncondensing) operating: 10 to 90% 
			●  Relative humidity, ambient (noncondensing) nonoperating and storage: 10 to 95% 
			●  Altitude, operating: -197 to 6500 ft (-60 to 2000m) 
			 | 
		
		
			| Approvals and compliance | 
			●  Safety compliance 
			●  CE Marking 
			●  UL 60950 
			●  CAN/CSA-C22.2 No. 60950 
			●  EN 60950 
			●  IEC 60950 
			●  TS 001 
			●  AS/NZS 3260 
			●  IEC60825 
			●  EN60825 
			●  21 CFR 1040 
			●  EMC compliance 
			●  FCC Part 15 (CFR 47) Class A 
			●  ICES-003 Class A 
			●  EN 55022 Class A 
			●  CISPR 22 Class A 
			●  AS/NZS 3548 Class A 
			●  VCCI Class A 
			●  EN 55024 
			●  EN 50082-1 
			●  EN 61000-6-1 
			●  EN 61000-3-2 
			●  EN 61000-3-3 | 
		
		
			| Fabric services | 
			●  Name server 
			●  Registered State Change Notification (RSCN) 
			●  Login services 
			●  Fabric Configuration Server (FCS) 
			●  Broadcast 
			●  In-order delivery | 
		
		
			| Advanced functions | 
			●  VSAN 
			●  NPV 
			●  IVR 
			●  Port channel with multipath load balancing 
			●  Flow-based and zone-based QoS | 
		
		
			| Supported Cisco optics, media, and transmission distances | 
			●  For detailed information about all supported transceivers, see Cisco MDS 9000 Family pluggable transceivers documentation | 
		
	
 
Bạn đang cần tư vấn về sản phẩm: DS-C9132T-MEK9 ?