Physical Specifications |
Backplane |
320 Gbps Virtual Chassis interconnect to combine up to 10 units as a single logical device |
Uplink Module Options |
4-port dual-mode 10GbE/1GbE module with pluggable SFP+/SFP optics |
Power Options |
• 550 W DC AFO and 550 W DC AFI; input voltage range 43.5-60 V max (+/- 0.5 V); dual input feed, dual load-sharing hot-swappable internal redundant power supplies
• Minimum number of PSUs required for fully loaded chassis: 1 per switch |
Dimensions (W x H x D) |
• 17.41 x 1.72 x 16.43 in. (44.21 x 4.32 x 41.73 cm)
• Desktop installation width noted above, rack-mount width: 17.5 in, (44.5 cm)
• Height: 1 U
|
System Weight |
• EX4300 switch (with no power supply or fan module): 13 lb (5.9 kg)
• EX4300 switch (with single power supply and two fan modules): 16.1 lb (7.3 kg)
• 350 W AC power supply: 2.4 lb (1.1 kg)
• SFP+ uplink module: 0.44 lb (0.2 kg)
• Fan module: 0.33 lb (0.15 kg) |
Environmental Ranges |
• Operating temperature: 32° to 113° F (0° to 45° C)
• Storage temperature: -40° to 158° F (-40° to 70° C)
• Operating altitude: up to 10,000 ft (3,049 m)
• Non-operating altitude: up to 16,000 ft (4,877 m)
• Relative humidity operating: 10% to 85% (noncondensing)
• Relative humidity non-operating: 0% to 95% (noncondensing) |
Cooling |
• Field-replaceable fans: 2
• Airflow: PSU-7.5 cubic feet per minute (CFM); fan-22 CFM
• Total maximum airflow throughput with two power supplies: 59 CFM |
Hardware Specifications |
Switching Engine Model |
Store and forward |
DRAM |
2 GB with ECC |
Flash |
2 GB |
CPU |
1.5 GHz Dual-Core PowerPC CPU |
GbE port density per system |
56 (48 host ports + four 40GbE ports + optional four-port 1/10GbE uplink module) |
Physical Layer |
• Time domain reflectometry (TDR) for detecting cable breaks and shorts
• Auto medium-dependent interface/medium-dependent interface crossover (MDI/MDIX) support
• Port speed downshift/setting maximum advertised speed on 10/100/1000BASE-T ports
• Digital optical monitoring for optical ports |
Physical Layer |
• Time Domain Reflectometry (TDR) for detecting cable breaks and shorts: 24P/24T and 48P/48T only
• Auto MDI/MDIX support: 24P/24T and 48P/48T only (all ports)
• Port speed downshift/setting max advertised speed on 10/100/1000BASE-T ports: 24P/24T and 48P/48T only, on all ports
• Digital optical monitoring for optical ports |
Packet-Switching Capacities (Maximum with 64-Byte Packets) |
496 Gbps |
Software Specifications |
Layer 2/Layer 3 Throughput (Mpps) (Maximum with 64 Byte Packets) |
369 Mpps (wire speed) |
Security |
• MAC limiting (per port and per VLAN)
• Allowed MAC addresses configurable per port
• Dynamic ARP inspection (DAI)
• IP source guard
• Local proxy ARP
• Static ARP support
• DHCP snooping
• Captive portal
• Persistent MAC address configurations
• Distributed denial of service (DDoS) protection (CPU control path flooding protection) |
Layer 2 Features |
• Maximum MAC addresses per system: 64,000
• Jumbo frames: 9216 Bytes
• Number of VLANs supported: 4093
• Range of possible VLAN IDs: 1 to 4094
• Virtual Spanning Tree (VST) instances: 510
• Port-based VLAN
• Voice VLAN
• Physical port redundancy: Redundant trunk group (RTG)
• Compatible with Per-VLAN Spanning Tree Plus (PVST+)
• Routed VLAN Interface (RVI)
• Uplink Failure Detection (UFD)
• ITU-T G.8032: Ethernet Ring Protection Switching
• IEEE 802.1AB: Link Layer Discovery Protocol (LLDP)
• LLDP-MED with VoIP integration
• Default VLAN and multiple VLAN range support
• MAC learning disable
• Persistent MAC learning (sticky MAC)
• MAC notification
• Private VLANs (PVLANs)
• Explicit congestion notification (ECN)
• Layer 2 protocol tunneling (L2PT)
• IEEE 802.1ak: Multiple VLAN Registration Protocol (MVRP)
• IEEE 802.1p: CoS prioritization
• IEEE 802.1Q: VLAN tagging
• IEEE 802.1X: Port Access Control
• IEEE 802.1ak: Multiple Registration Protocol
• IEEE 802.3: 10BASE-T
• IEEE 802.3u: 100BASE-T
• IEEE 802.3ab: 1000BASE-T
• IEEE 802.3z: 1000BASE-X
• IEEE 802.3ae: 10-Gigabit Ethernet
• IEEE 802.3ba: 40-Gigabit Ethernet
• IEEE 802.3af: Power over Ethernet
• IEEE 802.3at: Power over Ethernet Plus
• IEEE 802.3x: Pause Frames/Flow Control
• IEEE 802.3ah: Ethernet in the First Mile |
Spanning Tree |
• IEEE 802.1D: Spanning Tree Protocol
• IEEE 802.1s: Multiple instances of Spanning Tree Protocol (MSTP)
• Number of MST instances supported: 64
• Number of VLAN Spanning Tree Protocol (VSTP) instances supported: 510
• IEEE 802.1w: Rapid reconfiguration of Spanning Tree Protocol |
Link Aggregation |
• IEEE 802.3ad: Link Aggregation Control Protocol
• 802.3ad (LACP) support:
- Number of LAGs supported: 128
- Maximum number of ports per LAG: 16
• LAG load-sharing algorithm bridged or routed (unicast or multicast) traffic:
- IP: S/D IP
- TCP/UDP: S/D IP, S/D Port
- Non-IP: S/D MAC
• Tagged ports support in LAG |
Layer 3 Features: IPv4 |
• Maximum number of ARP entries: 64,000
• Maximum number of IPv4 unicast routes in hardware: 16,000 prefixes; 32,000 host routes
• Maximum number of IPv4 multicast routes in hardware: 8000 multicast groups; 16,000 multicast routes
• Routing protocols: RIPv1/v2, OSPF, BGP, IS-IS
• Static routing
• Routing policy
• Bidirectional Forwarding Detection (BFD)
• L3 redundancy: Virtual Router Redundancy Protocol (VRRP) |
Layer 3 Features: IPv6 |
• Maximum number of Neighbor Discovery (ND) entries: 32,000
• Maximum number of IPv6 unicast routes in hardware: 4000 prefixes; 15,000 host routes
• Maximum number of IPv6 multicast routes in hardware: 8000 multicast groups; 16,000 multicast routes
• Routing protocols: RIPng, OSPFv3, IPv6, ISIS
• Static routing |
Access control lists (ACLs) (Junos OS firewall filters) |
• Port-based ACL (PACL): Ingress and egress
• VLAN-based ACL (VACL): Ingress and egress
• Router-based ACL (RACL): Ingress and egress
• ACL entries (ACE) in hardware per system:
- Port-based ACL (PACL) ingress: 3072
- VLAN-based ACL (VACL) ingress: 3500
- Router-based ACL (RACL) ingress: 7000
- gress shared across PACL and VACL: 512
- Egress across RACL: 1024
- ACL counter for denied packets
• ACL counter for permitted packets
• Ability to add/remove/change ACL entries in middle of list (ACL editing)
• L2-L4 ACL |
Access Security |
• 802.1X port-based
• 802.1X multiple supplicants
• 802.1X with VLAN assignment
• 802.1X with authentication bypass access (based on host MAC address)
• 802.1X with VoIP VLAN support
• 802.1X dynamic ACL based on RADIUS attributes
• 802.1X Supported Extensible Authentication Protocol (EAP types): Message Digest 5 (MD5), Transport Layer Security (TLS), Tunneled TLS (TTLS), Protected Extensible Authenticated Protocol (PEAP)
• MAC authentication (RADIUS)
• Control plane DoS protection
• Radius functionality over IPv6 for authentication, authorization, and accounting (AAA)
• DHCPv6 snooping
• IPv6 neighbor discovery
• IPv6 source guard
• IPv6 RA guard
• IPv6 Neighbor Discovery Inspection
• Media Access Control security (MACsec)
|
High Availability |
• Redundant, hot-swappable power supplies
• Redundant, field-replaceable, hot-swappable fans
• Graceful Routing Engine switchover (GRES) for Layer 2 hitless forwarding and Layer 3 protocols on RE failover
• Graceful protocol restart (OSPF, BGP)
• Layer 2 hitless forwarding on RE failover
• Nonstop bridging: LACP, xSTP
• Nonstop routing: PIM, OSPF v2 and v3, RIP v2, RIPnG, BGP, BGPv6, ISIS, IGMP v1, v2, v3
• Online insertion and removal (OIR) uplink module |
Quality of Service (QoS) |
• L2 QoS
• L3 QoS
• Ingress policing: 1 rate 2 color
• Hardware queues per port: 12
• Scheduling methods (egress): Strict priority (SP), WDRR
• 802.1p, DiffCode (DSCP)/IP precedence trust and marking
• L2-L4 classification criteria: Interface, MAC address, Ethertype, 802.1p, VLAN, IP address, DSCP/IP precedence, TCP/UDP port numbers, and more
• Congestion avoidance capabilities: Tail drop, weighted random early detection (WRED) |
Multicast |
• IGMP: v1, v2, v3
• IGMP snooping
• Multicast Listener Discovery (MLD) snooping
• PIM-SM, PIM-SSM, PIM-DM |
Services and Manageability |
• Junos OS CLI
• Web interface
• Out-of-band management: Serial; 10/100/1000BASE-T Ethernet
• ASCII configuration
• Rescue configuration
• Configuration rollback
• Image rollback
• LCD management
• Element management tools: Juniper Networks Network and Security Manager (NSM)
• Remote performance monitoring
• Proactive services support via Advanced Insight Solutions (AIS) • SNMP: v1, v2c, v3
• RMON (RFC 2819) Groups 1, 2, 3, 9
• Network Time Protocol (NTP)
• DHCP server
• DHCP client and DHCP proxy
• DHCP relay and helper
• DHCP local server support
• RADIUS
• Junos Space Service Now for automated fault detection, simplified trouble ticket management, and streamlined operations
• TACACS+
• SSHv2
• Secure copy
• HTTP/HTTPs
• Domain Name System (DNS) resolver
• System logging
• Temperature sensor
• Configuration backup via FTP/secure copy |
Safety and Compliance
|
Safety Certifications |
• UL-UL60950-1 (First Edition)
• C-UL to CAN/CSA 22.2 No. 60950-1 (First Edition)
• TUV/GS to EN 60950-1, Amendment A1-A4, A11
• EN 60950-1 (2006 +A1:2009+A12:2010) Information Technology Equipment—Safety
• IEC 60950-1 (2005 +A1:2009) Information Technology Equipment—Safety |
Electromagnetic Compatibility Certifications |
• FCC 47CFR Part 15 Class A
• EN 55022 Class A
• ICES-003 Class A
• VCCI Class A
• AS/NZS CISPR 22 Class A
• CISPR 22 Class A
• EN 55024
• EN 300386
• CE |
NEBS |
GR-1089-Core: EMC and Electrical Safety for Network Telecommunications Equipment |
Environmental |
Reduction of Hazardous Substances (ROHS) 6/6 |
Telco |
• CLEI code |
Acoustic Noise in DBA |
39.7 |
Bạn đang cần tư vấn về sản phẩm: EX4300-48T-DC ?
Thiết bị chuyển mạch Switch juniper EX4300-48T-DC không hỗ trợ POE ạ.
Cho mình xin thông số DRAM và Flash của thiết bị mạng juniper EX4300-48T-DC.
Thiết bị chuyển mạch Switch Juniper EX4300-48T-DC có thông số DRAM là 2GB with ECC và thông số Flash là 2GB bạn nhé.
Chào bạn, gửi bạn datasheet của thiết bị chuyển mạch switch juniper EX4300-48T-DC nhé:
https://cnttshop.vn/storage/Datasheet/juniper%20EX4300.pdf
Báo giá Module quang EX-SFP-10GE-ER dùng cho thiết bị chuyển mạch switch juniper EX4300-48T-DC đã được gửi vào mail của bạn, bạn vui lòng check mail ạ.
Thông số GbE port density per system của thiết bị mạng juniper EX4300-48T-DC là 56 (48 host ports + four 40GbE ports + optional four-port 1/10GbE uplink module) bạn nhé.