CÔNG TY TNHH CÔNG NGHỆ VIỆT THÁI DƯƠNG
Logo CNTTShop.vn

NTT03, Line 1, Thống Nhất Complex, Thanh Xuân, Hà Nội.
Danh mục sản phẩm

Network Management

Enter [Network Design], you can see the information of each network, including the number of network alarms (not ignored), the number of online devices and the total number of devices:

Network Management

Figure 1-5-1 Network Management

You can set the switch of AP auto recovery and flow threshold for the network. After the AP self- healing function is enabled, if the POE port traffic of the device is lower than the traffic threshold, the port will be automatically restarted without an alarm. If it is still below the threshold after restarting, do not restart again (restart only once in a single day):

AP auto recovery switch and traffic threshold

Figure 1-5-2 AP auto recovery switch and traffic threshold

You can set the switch of terminal collection for the network, which is closed by default. After it is enabled, the terminal data will be collected in [1.8.1 Terminal Overview]:

Terminal acquisition switch

Figure 1-5-3 Terminal acquisition switch