CÔNG TY TNHH CÔNG NGHỆ VIỆT THÁI DƯƠNG
Logo CNTTShop.vn

NTT03, Line 1, Thống Nhất Complex, Thanh Xuân, Hà Nội.
Danh mục sản phẩm

Configure Abnormality Recovery Function

When there is a PoE power supply abnormality, the abnormality recovery function is supported, including automatic recovery and manual recovery.

Configuration Condition

Before configuring the abnormality recovery function, ensure that:

  • The global PoE function is enabled.
  • The interface PoE function is enabled.

Configure the Time for Recovery from a Power Supply Abnormality of an Interface

If a PSE detects abnormal power supply status of an interface while powering PDs, it automatically disables the PoE function of the interface. After the time for recovery from a power supply abnormality elapsed, it enables the PoE function again, and tries to supply power to the PD of the interface.

Table 12-17 Configuring the Time for Recovery from a Power Supply Abnormality of an Interface

Step

Command

Description

Enter the global configuration mode.

configure terminal

-

Enter the layer-2 Ethernet interface configuration mode.

interface interface-name

-

Configure the time for recovery from a power supply abnormality of an interface.

power recover-time time-value

Optional.

By default, the time for recovery from a power supply abnormality is 0 minute, indicating recovery immediately.

Restart PoE Power Supply

When a PoE power supply abnormality occurs or the PoE power supply is abnormal, you can manually hot restart the PoE power supply to try to recover from the abnormal status.

Table 12-18 Configuring the Time for Recovery from a Power Supply Abnormality of an Interface

Step

Command

Description

Restart the PoE power supply.

power reload { all | system-

id }

Mandatory.

note


  • During the power supply restart process, if you run the power reload command again, the system prompts command execution failure.