Upgrade the Bootloader
Configuration Condition
None
Upgrade the Bootloader Program
Table 11‑4 Upgrade the Bootloader program
Step
|
Command
|
Description
|
Enter the Bootloader configuration mode
|
None
|
Mandatory.
After the device is powered on, press the Ctrl + C keys to enter the Bootloader configuration mode. After you enter the mode, the " RTL93xx#" is prompted.
|
Start the tftp service on the PC
|
|
Mandatory
Copy the new bootloader version used for upgrading to the root directory of tftp, used by the device to download the version file via tftp.
|
Upgrade the Bootloader program
|
update bootloader filename ge0 local-ip-addr host-ip-addr [gatewayip] [ netmask]
|
Mandatory
|
Back up the bootloader program
|
bootloaderbak
|
Optional
|
-
Bootloader system program adopts dual-bootloader backup mode, which is divided into the master bootloader program and standby bootloader program. With the upgrade command, you can only upgrade the version of the master bootloader, while the standby bootloader program will remain unchanged.
- After upgrading the Bootloader system program, use the command reset or power off to restart the device, and then, you can use the latest Bootloader system program.
- After the system is loaded successfully, you can use the sysupdate command to upgrade.