Configure EIPS Reliability
Configuration Condition
No
Configure EIPS Standby Node
To improve the EIPS ring reliability, the standby node works by replacing the master node when the master node breaks down.
The standby node is configured on the transmission node that is directly connected to the master node.
Table 3–12 Configure EIPS standby node
Step
|
Command
|
Description
|
Enter the global configuration mode
|
configure terminal
|
-
|
Enter the EIPS configuration mode
|
eips ring ring-id { master | transit | edge | assistant } [ segment ]
|
-
|
Configure the specified transmission node as standby node
|
backup master
|
Mandatory
By default, the standby node is not configured.
|
Configure EIPS Uni-directional Detection
Enable the uni-directional detection function on the port or the port group.
Table 3–13 Configure the EIPS uni-directional detection on the port
Step
|
Command
|
Description
|
Enter the global configuration mode
|
configure terminal
|
-
|
Enter the L2 Ethernet interface configuration mode
|
interface interface-name
|
-
|
Configure EIPS uni-directional detection on the port
|
eips udld interval [ value ]
|
Mandatory
By default, the uni-directional detection function on the port is not enabled.
|