Hà Nội: NTT03, Line 1, Thống Nhất Complex, 82 Nguyễn Tuân, Thanh Xuân, Hà Nội. ● HCM: Số 31B, Đường 1, Phường An Phú, Quận 2 (Thủ Đức), TP HCM. ===> Đơn Vị Hàng Đầu Trong Lĩnh Vực Cung Cấp Thiết Bị Security - Network - Wifi - CCTV - Conference - Máy chủ Server - Lưu trữ Storge.
Danh mục sản phẩm

Configure ULFD Parameters

Configuration Condition

Before configuring the ULFD parameters, first complete the following task:

  • Enable the ULFD function

Configure Sending Period of ULFD Detection Packet

ULFD periodically sends the detection packets to detect whether the network has the uni-directional link. We can modify the sending period of the detection packets according to the actuality of the network. The sending period of the detection packets is 7-90s. By default, it is 15s.

Table 2–4 Configure the sending period of the ULFD detection packet

Step

Command

Description

Enter the global configuration mode

configure terminal

-

Configure the sending period of the ULFD packet

ulfd message time time-value

Optional

By default, the sending period of the uni-directional detection packet is 15s.

Reset Ethernet Interface Disabled by ULFD

If ULFD detects the uni-direction and disables the Ethernet interface, to re-enable the ULFD detection function of the Ethernet interface, the user needs to perform the reset operation manually. The operation sets the Ethernet interface to UP and re-enables the ULFD detection.

Table 2–5 Reset the Ethernet interface disabled by ULFD

Step

Command

Description

Reset the Ethernet interface disabled by ULFD

ulfd reset [ interface interface-name ]

Optional

By default, do not execute the reset operation automatically after the Ethernet interface is disabled.