Configure EIPS Timer
Configuration Condition
Before configuring the EIPS timer, first complete the following task:
- Configure EIPS basic functions.
Configure EIPS Timer
For the master nodes and edge control nodes in the hierarchical mode, a timer is used to control the sending frequency and the timeout for receiving the Hello packet. For the transmission nodes, a block timer is used to control the duration for the transmission node transiting from the fault recovery status to the complete status.
Table 3–14 Configure EIPS timer
Step
|
Command
|
Description
|
Enter the global configuration mode
|
configure terminal
|
-
|
Enter the EIPS configuration mode
|
eips ring ring-id { master | transit | edge | assistant } [ segment ]
|
-
|
Configure the timer for EIPS node
|
timer { hello | receive | block } timer-value
|
Mandatory
By default, the timeout of the hello timer is 1s; for the receiving timer, it is 5s; for the blocking timer, it is 10s.
|
-
The timer for sending the hello packet can be configured only on the master nodes or the edge control nodes and the blocking timer can be configure only on the transmission nodes.
-
If the standby nodes are configured, the timeout duration for the Hello timer on the master nodes cannot be configured as 0.